,Model##Other##,Nominal Tonnage##Other##,Fan Motor HP##Electrical_Power##Horsepower,Number of Fan Motors##Other##,Minimum Flow##Piping_Flow##us_gallons_per_minute,Maximum Flow##Piping_Flow##us_gallons_per_minute,Box Size##Other##,Unit Airflow##hvac_air_flow##cubic_feet_per_minute,Length##Length##Inches,Pan Width##Length##Inches,Lower Height##Length##Inches,Casing Width##Length##Inches,Casing Center Offset##Length##Inches,Casing Height##Length##Inches,Inlet Offset##Length##Inches,Inlet Elevation##Length##Inches,Number of Nozzles##Other##,PC1##Other##,PC2##Other##,E1##Other##,E2##Other##,Height##Length##Inches,Mounting Bolt Centerline##Length##Inches,Mounting Bolt Edge Distance##Length##Inches,Center Bolt Spacing##Length##Inches,Recommended Support Arrangement##Other##,Makeup Pipe Size##Pipe_Size##Inches,Drain Elevation##Length##Inches,Drain from Blankoff##Length##Inches,Outlet Elevation##Length##Inches,Outlet from Blankoff##Length##Inches,Overflow Elevation##Length##Inches,Overflow from Blankoff##Length##Inches,Makeup Elevation##Length##Inches,Makeup from Blankoff##Length##Inches,Intake Setback##Length##Inches,Intake Base Elevation##Length##Inches,Fan Housing Radius##Length##Inches,Fan Housing Setback##Length##Inches,Fan Housing Width##Length##Inches,Fan Housing Elevation##Length##Inches,Fan Spacing##Length##Inches,Fan Configuration##Other##,Air Intake Clearance##Length##Feet,Operating Weight##Force##Pounds_Force,Minimum Inlet Size##Pipe_Size##Inches,Minimum Outlet Size##Pipe_Size##Inches,Box Classification##Other##
VT1-825-P,VT1-825-P,825,40.0,3,1543,4268,12x36,247590,139.75,142,100,140.75,0.625,54.625,7.75,146.875,450,0.1048635,0.010008898,2,2.28,154.625,127.5,1.375,17.25,Series V Plan A-12 3 Cell : Configuration,3,6.625,3.375,13.5,27.125,29,4.75,40.5,65.25,3,4,48,20,24,54,42,Series V 3 Fanwscrn : Configuration,17,45980,8,10,5
VT1-921-O,VT1-921-O,921,30.0,3,1854,4455,12x36,223050,139.75,142,100,140.75,0.625,77.375,9.5,167.875,450,0.1048635,0.010008898,2,2.28,177.375,127.5,1.375,17.25,Series V Plan A-12 3 Cell : Configuration,3,6.625,3.375,13.5,27.125,29,4.75,40.5,65.25,3,4,48,20,24,54,42,Series V 3 Fanwscrn : Configuration,17,47750,8,10,5
VT1-1020-P,VT1-1020-P,1020,40.0,3,2055,4929,12x36,244650,139.75,142,100,140.75,0.625,77.375,9.5,167.875,450,0.1048635,0.010008898,2,2.28,177.375,127.5,1.375,17.25,Series V Plan A-12 3 Cell : Configuration,3,6.625,3.375,13.5,27.125,29,4.75,40.5,65.25,3,4,48,20,24,54,42,Series V 3 Fanwscrn : Configuration,17,48320,8,10,5
VT1-1125-P,VT1-1125-P,1125,40.0,3,2382,5211,12x36,237900,139.75,142,100,140.75,0.625,94.125,9.5,184.625,450,0.1048635,0.010008898,2,2.28,194.125,127.5,1.375,17.25,Series V Plan A-12 3 Cell : Configuration,3,6.625,3.375,13.5,27.125,29,4.75,40.5,65.25,3,4,48,20,24,54,42,Series V 3 Fanwscrn : Configuration,17,51230,8,10,5
VT1-1200-Q,VT1-1200-Q,1200,50.0,3,2544,5550,12x36,255450,139.75,142,100,140.75,0.625,94.125,9.5,184.625,450,0.1048635,0.010008898,2,2.28,194.125,127.5,1.375,17.25,Series V Plan A-12 3 Cell : Configuration,3,6.625,3.375,13.5,27.125,29,4.75,40.5,65.25,3,4,48,20,24,54,42,Series V 3 Fanwscrn : Configuration,17,51350,8,10,5
VT1-1245-R,VT1-1245-R,1245,60.0,3,2643,5751,12x36,270750,139.75,142,100,140.75,0.625,94.125,9.5,184.625,450,0.1048635,0.010008898,2,2.28,194.125,127.5,1.375,17.25,Series V Plan A-12 3 Cell : Configuration,3,6.625,3.375,13.5,27.125,29,4.75,40.5,65.25,3,4,48,20,24,54,42,Series V 3 Fanwscrn : Configuration,17,51710,8,10,5
VT1-1335-S,VT1-1335-S,1335,75.0,3,2841,6157,12x36,290550,139.75,142,100,140.75,0.625,94.125,9.5,184.625,450,0.1048635,0.010008898,2,2.28,194.125,127.5,1.375,17.25,Series V Plan A-12 3 Cell : Configuration,3,6.625,3.375,13.5,27.125,29,4.75,40.5,65.25,3,4,48,20,24,54,42,Series V 3 Fanwscrn : Configuration,17,51770,8,10,5